Material Safety Data Sheet
Complies with OSHA Communication Standard
29 CFR 1910.1200
|
Product Name on Label DW-R8 and DW-R10
|
Manufacturer’s Contact Information
ALX Enterprises LLC
|
197 Evergreen Drive
|
Springfield, TN 37172
|
Office- 615-489-4444
|
Emergency Number- 615-945-8144
|
Manufacturers Hazard Rating
|
|
Toxicity – 1
|
Fire – 1
|
Reactivity – 0
|
Special – 0
|
|
Hazard Rating Scale
|
Extreme=4
|
High=3
|
Moderate=3
|
Slight=1
|
Insignificant=0
|
Ingredients and Identity Information
Components
|
%
|
OSHA
|
PEL
|
ACGIH TLV
|
Other limits
|
Sulfonated styrene-divinylbenzene copolymer in hydrogen form
|
97-99
|
N/A
|
N/A
|
N/A
|
N/A
|
Water
|
1-3
|
N/A
|
N/A
|
N/A
|
N/A
|
Physical/Chemical Characteristics
Appearance and odor
|
Amber to black spherical beads with no odor
|
Melting point
|
N/A
|
Vapor pressure (mm/Hg)
|
N/A
|
Vapor Density
|
N/A
|
Evaporation Rate
|
N/A
|
Melting point
|
N/A
|
Vapor pressure (mm/Hg)
|
N/A
|
Fire and Explosion Hazard Data
NFPA Fire Hazard Class
|
1
|
Flash Point (Deg. C)
|
N/A
|
Auto Ignition Temperature (Deg. C)
|
Greater than 500
|
Flammable Limits
|
N/A
|
Conditions of Flammability
|
Not Determined
|
Extinguishing Media
|
CO2, Dry Chemical, Water Fog
|
Special Fire Fighting Procedures
|
Wear MSHA/NIOSH approved, pressure demand, self contained breathing apparatus
|
Unusual Fire and Explosion Hazards
|
None
|
Reactivity Data
NFPA Reactivity Rating
|
1
|
Conditions to avoid
|
Temperatures above 430 degrees F (220 degrees C)
|
Stability
|
Stable
|
Hazardous Polymerization
|
None
|
Extinguishing Media
|
CO2, Dry Chemical, Water Fog
|
Incompatibility
|
Avoid strong oxidizing agents and concentrated nitric acid
|
Hazardous decomposition by-products
|
Styrene monomer, divinylbenzene, CO, CO2, SO2 and SO3
|
Health Hazard Data
NFPA Health Hazard
|
1
|
Exposure Limits
|
ND
|
Mutagenicity
|
ND
|
Carcinogenicity
|
ND
|
Reproductive Toxicity
|
ND
|
Tetratogenicity
|
ND
|
Irritancy of Product
|
Eyes and Skin
|
OSHA Regulated?
|
N/A
|
Effect of acute exposure
|
Can produce mechanical irritation of eyes
|
Emergency and First Aid Procedures
|
Flush eyes and skin with copious quantities of water for 15 minutes. If irritation persists, see a physician
|
Precautions for Safe Handling and Use
Precautions in case of spill or release
|
Product will cause a slip hazard on hard surfaces. Sweep up immediately for re-use or disposal
|
Precautions for handling and storage
|
Keep containers sealed to avoid exposure to humidity and water. Product will swell 100% on exposure to moisture. Expansion of product could cause containers to burst. Store in cool dry area (above 32 degrees F and below 120 degrees F).
|
Special Precautions for handling and storage
|
Avoid contact with Nitric acid and strong oxidizing agents.
|
Waste Disposal method
|
As supplied, new and used ion exchange resin is not considered as hazardous waste. Used resin may meet the regulatory definition of hazardous waste as a result of its service or absorbed contaminants. (Refer to 40 CFR 261) Regulatory agencies and disposal sites may require verification of the hazardous or non-hazardous properties.
|
Control Measures
Personal Protective Equipment
|
Wear impervious gloves and splash goggles when handling ion exchange resin
|
Other Protective Clothing or Equipment
|
Wear trousers and long sleeve shirts to avoid skin exposure.
|
Work and Hygenic Practices
|
Flush product from hands with soapy water. Clean up all spilled product immediately to avoid slip hazards
|
Precautions during application of product
|
Product will swell during use by approximately 100%. Maintain adequate freeboard in process vessels to allow for expansion
|
Regulatory Information and References
Section 302 Reporting if above
|
None
|
Section 304 Reporting if above
|
None
|
Section 313 Reporting required
|
No
|
CERCLA reporting required if above
|
None
|
RCRA reporting required
|
No
|
Canadian WHMIS Classification
|
Other
|
D.O.T. Hazard Name
|
Not required by D.O.T.
|
D.O.T. ID Number
|
N/A
|
D.O.T. Hazard Class
|
N/A
|
References
The data and recommendations presented are based on our research and the research of others, and are believed to be accurate. However, no warranty is expressed or implied regarding the accuracy of these data or the results to be obtained from the use thereof. ALX Enterprises LLC assumes no responsibility for the injury to customers or third persons caused by the material if reasonable safety procedures are not adhered to as stipulated in the data sheet. Additionally, since actual use by others is beyond our control, no guarantee, expressed or implied is made by ALX Enterprises LLC as to the effects of such use, the results to be obtained, or the safety and toxicity of the product. ALX Enterprises LLC assumes no liability arising out of the use, or misuse, by others, of the product referred to herein. Information provided herein is provided by ALX Enterprises LLC solely for the customer’s assistance in complying with the Occupational Safety and Health Act of 1970 and regulations hereunder. Any other use is prohibited.
|
|